Volver al menú anterior
  Sequence and counter pressure valves  
  Modular assembly. Model 12. Size CETOP 3 NG 6.  
 
 


These sequence valves are used to keep a predetermined pressure in one sense. The valve remains closed until said pressure doesn’t exceed the regulating value. The construction of this valve is that of a direct action valve with displaceable cam, which is normally manufactured with internal piloting and drainage. The piloting pressure is taken on the P channel or on the A channel according to the model. The drainage is internally connected with the T channel.

 
 
-
Modular assembly.
- Maximum pressure 320 Kg/cm²
- Maximum flow 40 l/min.
- Two surface assembly models CETOP 3 NG 6:
VS-M-12-#-PT
VS-M-12-#-TA
- Configuration in two regulation ranges:
B > 20 - 80 Kg/cm²
F > 50 - 250 Kg/cm²

 
 
  VS-M-12-#-P#  
 
   
HYDRAULIC SCHEME
FIXING:
  4 Metric Screws Ø 5x50.
Communication holes: A, B, P, T, Ø 8.
BOARD ASSEMBLY: CETOP 3 / NG 6
 

PM-SH-12-#-#
PM-M-SH-12-#V-#
PM-SH-12-#-#-RP-#
PM-M-SH-12-#V-RP-#

CODIFICATION
   
MODEL
WEIGHT (Kg)

PRESSURE RANGE
(Kg/cm²)

FLOW VOLUME
(l/min)
A, B, P & T CONNECTION
VS-M-12-B-P#
1,4
20 - 80
40
Ø 6
VS-M-12-F-P#
50 - 250
 
 
 
 
 
  Volver arriba
   
 
 